Silicon Labs /SiM3_NRND /SIM3C167_B /SSG_0 /CONTROL

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as CONTROL

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (NORMAL)EX0INVEN 0 (NORMAL)EX1INVEN 0 (NORMAL)EX2INVEN 0 (NORMAL)EX3INVEN 0 (DISABLED)EX0EN 0 (DISABLED)EX1EN 0 (DISABLED)EX2EN 0 (DISABLED)EX3EN 0 (IDLE)STATUS

EX3EN=DISABLED, STATUS=IDLE, EX3INVEN=NORMAL, EX1INVEN=NORMAL, EX2INVEN=NORMAL, EX1EN=DISABLED, EX2EN=DISABLED, EX0EN=DISABLED, EX0INVEN=NORMAL

Description

Module Control

Fields

EX0INVEN

Output 0 Invert Enable.

0 (NORMAL): Do not invert the Pulse Generator output on EX0.

1 (INVERT): Invert the Pulse Generator output on EX0.

EX1INVEN

Output 1 Invert Enable.

0 (NORMAL): Do not invert the Pulse Generator output on EX1.

1 (INVERT): Invert the Pulse Generator output on EX1.

EX2INVEN

Output 2 Invert Enable.

0 (NORMAL): Do not invert the Pulse Generator output on EX2.

1 (INVERT): Invert the Pulse Generator output on EX2.

EX3INVEN

Output 3 Invert Enable.

0 (NORMAL): Do not invert the Pulse Generator output on EX3.

1 (INVERT): Invert the Pulse Generator output on EX3.

EX0EN

Output 0 Enable.

0 (DISABLED): Disable the EX0 Pulse Generator output.

1 (ENABLED): Enable the EX0 Pulse Generator output.

EX1EN

Output 1 Enable.

0 (DISABLED): Disable the EX1 Pulse Generator output.

1 (ENABLED): Enable the EX1 Pulse Generator output.

EX2EN

Output 2 Enable.

0 (DISABLED): Disable the EX2 Pulse Generator output.

1 (ENABLED): Enable the EX2 Pulse Generator output.

EX3EN

Output 3 Enable.

0 (DISABLED): Disable the EX3 Pulse Generator output.

1 (ENABLED): Enable the EX3 Pulse Generator output.

STATUS

SSG Module Status.

0 (IDLE): The SSG module is idle and the Pulse Generator is not operating.

1 (ACTIVE): The SSG module is active and the Pulse Generator is counting.

Links

()